
Edwards SAPIEN Transcatheter Heart Valve
New concept in the treatment of aortic valve disease
Transapical aortic valve implantation (TA-AVI) is a new therapeutic strategy, which has been implemented successfully into clinical practice in several hundred patients suffering symptomatic aortic stenosis and an increase perioperative risk during the past two years. The Edwards SAPIEN™ prosthesis has been used.
Transapical access is based on decades of clinical experience with de-airing the heart, through the tip (apex) of the left ventricle, during routine cardiac surgical interventions. Insertion of a catheter and later-on closure through the apex is possible in a relatively uncomplicated manner. An anterolateral minithoracotomy is a simple and standardized access to the apex. It is applicable in almost all patients and they can be extubated soon afterwards. This procedure can even be performed without intubation under regional anaesthesia in some patients.
From the apex of the left ventricular, the aortic valve is almost within reach. The major advantage of the TA access is the direct and antegrade approach of the aortic valve. Thanks to the short distance and the direct access, very exact positioning of an aortic valve prosthesis inside the stenosed native valve is possible from the left ventricular apex. In addition, there is minimal manipulation in the aortic arch with this technique. This is definitively associated with minimal risk of mobilizing intravascular calcifications and thus with a minimal stroke risk. The lower stroke risk of the transapical, in comparison to the transfemoral aortic valve implantation technique, has become evident in all published series in medical literature.
All these procedures are being performed by a specialized team of cardiac surgeons and cardiologists together with anaesthetists. High quality imaging is required and ideally the procedures should be performed in the setting of a hybrid operative theatre. This includes all operative capabilities together with high quality fluoroscopic imaging.
TA-AVI is being performed as an off-pump procedure. Femoral guidewires are being placed to be able to convert to cardiopulmonary bypass for the safety of the patient. The apex is reached by means of an anterolateral minithoracotomy in the fifth or sixth intercostal space. Pursestring sutures are placed at the apex. Valve implantation is then performed over guidewires that are antegradely inserted under fluoroscopic visualization. The apex can be safely closed using the prepositioned pursestring sutures afterwards. The chest is closed in a routine fashion. The patient can then be extubated soon.
The Valve in a valve technique allows for implantation of a transcatheter xenograft inside a degenerated conventional xenograft that has been implanted years ago. Basically, the same procedural steps are applied. In parallel to TA-AVI the technique of Valve in a valve implantation has also been successfully introduced into clinical practice.
by Professor Thomas Walther
This article was published on 09/02/2008
Search
Service
Company News
Accu-Chek® Combo – put effective diabetes management into action
At the annual congress of the European Association for the Study of Diabetes (EASD) this year in Rome, Roche Diabetes Care introduced Accu-Chek Combo – the insulin pump system that combines an insulin pump with an intelligent glucose monitoring system, a bolus calculator, and an integrated pump remote-control.
Products redesigned to help patients simplify life with diabetes
Bayer HealthCare Diabetes Care unveiled the new
CONTOUR® blood glucose meter with enhanced testing features at the 44th Annual Meeting of the European Association for the Study of Diabetes in Rome, Italy.
Technical infrastructure for EU funded R-bay project
Carestream Health is a major technical infrastructure provider to the EU-funded R-Bay validation project, which aims to address the uneven spread of radiologists across member states. CARESTREAM Radiology and Information Management Solutions are driving the initial test platform for the project by facilitating remote reporting of images from hospitals in Denmark, Finland and Czech Republic by clinical providers in Estonia, Lithuania and the Netherlands.